Incoming seed is examined to determine embryo count to help decide how much seed should be sown, and/or which capsule would be the best to sow. Permanent sample slides are also prepared. Each separate package of seed is examined because these are generally from separate capsules, which is what we request from our donors.
TN6231 Number of capsules harvested: 2
Seed Assay Number:
5351
Packet Code Number:
1A05351AZ
Harvest date:
09/02/2008
Received as:
Green capsule
Date Received:
09/05/2008
Number of Capsules Combined:
1
Comments:
Packet received was a folded coffee filter.
Capsule appears clean and intact.
Seed is light yellow to the naked eye, and free flowing. Only a small quantity of seed was received. Small seeds are short, sometimes curved, and have small sized elongated dense embryos toward the pointed end which are 3/4 the length of the seed.
Seeds that appeared to have
good embryos, by count:
46%
Photographed with transmitted light.
Scale1 mm or 0.040 inches Photo by Lacey Powell
Photographed with reflected light.
Scale1 mm or 0.040 inches Photo by Lacey Powell
Seed Assay Number:
5352
Packet Code Number:
1A05352AY
Harvest date:
09/02/2008
Received as:
Green capsule
Date Received:
09/05/2008
Number of Capsules Combined:
1
Comments:
Packet received was a folded coffee filter.
Capsule appears clean and intact.
Seed is pale yellow to the naked eye, and free flowing. Only a small quantity of seed was received, so no sample was taken, but appears to be similar to that in assay 5351.